Designing a CSM wall in Belgium
Programme
- Determining wall embedment depth based on required bearing capacity, passive resistance mobilisation and dewatering requirements
- Modelling:
- Non-horizontal ground levels
- Surface loads
- Loads directly applied to the wall
- Groundwater (phreatic levels, piezometric heads and Kastner’s method)
- Performing calculations with different sets of partial factors: GGT (including the possible application of the simplified method), ULS DA1-2, and ULS DA1-1 depending on the assigned risk class
- Using CP to model different construction phases for anchored cutter soil mix walls
- How the software handles bending stiffness and strength checks during iteration, and how it determines the optimal anchor row
Target audience
- Both clients and non-clients
- Engineering firms and contractors with internal design teams (geotechnical engineers)